Notable Features:
  • Compact, Rugged and Quiet
  • No tools required to change flow rates
  • Flow setting is saved in memory for next day quick start
  • Battery pack rechargeable while attached or separately
  • Stainless steel belt clip with built-in tripod connector
  • One-hour rechargeable batteries and extended run triple packs
  • High impact steel fiber filled Lexan case, antistatic and RFI shielded
  • "Auto-restart" within one minute of a flow fault
  • Flows up to 4 LPM for special cyclone requirements
  • Low flows, 5-800 cc/m, with Universal Low flow Sorbent Tube holder
  • High backpressure capable for 25mm 0.45µ asbestos filters
  • Built in washable stainless steel 100 micron filter for economy of use
  • One year warranty
  • Intrinsically Safety Approved

Email or Contact Us for pricing or information!


GENERAL DESCRIPTION:
The ECONOAIR L-4 is a low-cost high-performance personal air sampling pump. It is a "no frills" model designed for sampling of asbestos, lead and other airborne contaminates. The rugged compact design features a rechargeable NiMH battery with available one-hour recharger. The sealed pump case protects the internal components from dust, fibers and moisture. Simplicity of its operation features a "Set it and Forget it" flows at 2.0, 2.5, 3.0 LPM’s, maintained within 5% for full constant flow compensation using 37 and 25 mm cassettes interchangeable. This insures accurate sample volumes based on the run time. The ECONOAIR L-4, is capable of delivering up to 4.0 LPM for periods exceeding 8 hours. Bright LED's indicate pump ON, Flow Fault or a Low Battery. Flow from 5 to 800 cc/m may be obtained using optional Low Flow Holder.
 
Total Flow Range: 0.005-4 LPM (5-4000 cc.min)
(Flows 5-800 cc/m requires Universal Low Flow Holder)

LED’s Operational Conditions: Green LED indicates pump is running; Orange LED indicates a flow fault; Red LED indicates a low battery

Power: Rechargeable NiMH Batteries; 4.8Vm 2.15 Ah

Operating Temperature Range: 32º to 104ºF (0º to 40ºC)

Case: Polycarbonate steel fiber filled; RFI-shielded and antistatic

Size: 4.5"H × 4"W × 2"D (11.4 × 10.2 × 5 cm)

Accuracy: ± 5% of the flow set point

Pump Run time with sampling filters

 

Flowrate in LPM

Filter type and size

1.5

2.0

2.5

3.0

4.0

37mm 0.8µ PVC

19 hr

15 hr

14 hr

12 hr

10 hr

37 mm 0.8µ MCE

19 hr

15 hr

13 hr

11 hr

9 hr

25 mm 0.8µ MCE

15 hr

10 hr

9 hr

8 hr

25 mm 0.45µ MCE

10 hr

7.5 hr

 